Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Tumori ; 107(2): 132-138, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32552398

RESUMO

PURPOSE: To investigate the agreement between automated breast ultrasound (ABUS) and hand-held ultrasound (HHUS) in surveillance of women with a history of breast cancer in terms of recurrences or new ipsilateral or contralateral breast cancer. METHODS: The institutional review board approved this retrospective study and informed consent was waived. From April to June 2016, women with dense breasts undergoing annual surveillance with mammography and HHUS after breast-conserving surgery were offered supplemental ABUS (Invenia). HHUS was performed by a breast radiologist and ABUS by a trained technician. Images were reviewed by 2 breast radiologists. A per-patient BI-RADS category was independently assigned in all cases and categories were dichotomized into negative (1, 2, 3) and positive (4, 5). Cohen κ, McNemar, and Wilcoxon statistics were used. Final pathology was used as reference standard for malignant lesions. RESULTS: A total of 154 women (mean age 62±11 years) were enrolled. Time from surgery was a mean of 8±6 years. Cancer prevalence was 4/154 (2.6%). Interreader agreement for ABUS was 1. Intermethod interreader agreement for HHUS and ABUS was substantial for BI-RADS categories (κ = 0.785) and for dichotomic assessment (κ = 0.794). There was no difference in dichotomic assignment between 2 readers (p = 0.5) but a significant difference in assigning BI-RADS categories (p < 0.05). CONCLUSIONS: A substantial agreement resulted between HHUS and ABUS in surveillance of women with a previous history of breast cancer. In particular, ABUS recognized all cancers detected by HHUS and could play a role in first-level surveillance of women at intermediate risk.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Mastectomia Segmentar/métodos , Ultrassonografia Mamária/métodos , Ultrassonografia/métodos , Idoso , Mama/cirurgia , Neoplasias da Mama/cirurgia , Humanos , Mamografia/métodos , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Recidiva Local de Neoplasia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
Eur Radiol ; 29(9): 4544-4554, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30796572

RESUMO

OBJECTIVES: To compare postnatal magnetic resonance imaging (MRI) with the reference standard computed tomography (CT) in the identification of the key features for diagnosing different types of congenital lung malformation (CLM). METHODS: Respiratory-triggered T2-weighted single-shot turbo spin echo (ss-TSE), respiratory-triggered T1-weighted turbo field echo (TFE), balanced fast field echo (BFFE), and T2-weighted MultiVane sequences were performed at 1.5 T on 20 patients prospectively enrolled. Two independent radiologists examined the postnatal CT and MRI evaluating the presence of cysts, hyperinflation, solid component, abnormal arteries and/or venous drainage, and bronchocele. Diagnostic performance of MRI was calculated and the agreement between the findings was assessed using the McNemar-Bowker test. Interobserver agreement was measured with the kappa coefficient. RESULTS: CT reported five congenital pulmonary airway malformations (CPAMs), eight segmental bronchial atresias, five bronchopulmonary sequestrations (BPS), one congenital lobar overinflation, one bronchogenic cyst, and three hybrid lesions. MRI reported the correct diagnosis in 19/20 (95%) patients and the malformation was correctly classified in 22/23 cases (96%). MRI correctly identified all the key findings described on the CT except for the abnormal vascularization (85.7% sensitivity, 100% specificity, 100% PPV, 94.1% NPV, 95% accuracy for arterial vessels; 57.1% sensitivity, 100% specificity, 100% PPV, 84.2% NPV, 87% accuracy for venous drainage). CONCLUSIONS: MRI can represent an effective alternative to CT in the postnatal assessment of CLM. In order to further narrow the gap with CT, the use of contrast material and improvements in sequence design are needed to obtain detailed information on vascularization, which is essential for surgical planning. KEY POINTS: • Congenital lung malformations (CLMs) can be effectively studied by MRI avoiding radiation exposure. • Crucial features of CLM have similar appearance when comparing CT with MRI. • MRI performs very well in CLM except for aberrant vessel detection and characterization.


Assuntos
Pulmão/anormalidades , Pulmão/diagnóstico por imagem , Cisto Broncogênico/diagnóstico por imagem , Sequestro Broncopulmonar/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Lactente , Recém-Nascido , Pneumopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Projetos Piloto , Cuidado Pós-Natal/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
3.
Ultrasonography ; 37(4): 315-322, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29462847

RESUMO

PURPOSE: The purpose of this study was to validate the role of the total malignancy score (TMS) in identifying thyroid nodules suspicious for malignancy through the sum of their ultrasound features. METHODS: The local ethical committee approved this prospective observational study. We examined 231 nodules in 231 consecutive patients (164 females and 67 males; age range, 20 to 87 years; median age, 59 years; interquartile range, 48 to 70 years) who underwent ultrasound followed by fine-needle aspiration cytology (FNAC). The nodules were further classified using the TMS, which considers ultrasound features (number, echogenicity, structure, halo, margins, Doppler signal, calcifications, and growth), and the Bethesda System for Reporting Thyroid Cytopathology (TBSRTC), which considers cytological features. Patients with non-negative nodules (TBSRTC categories III to VI) underwent histological analysis, repeated FNAC, or 2 years of regular ultrasound follow-up. The associations between the final diagnosis, each of the ultrasound features, and the TMS were estimated using the chi-square test, the Mann-Whitney U test, and multivariate logistic regression. A receiver operating characteristic (ROC) curve was used to evaluate the diagnostic accuracy of the TMS. RESULTS: On ultrasound, 47% of the nodules (108 of 231) had a TMS >3, 18% (42 of 231) had a TMS of 3, and 35% (81 of 231) had a TMS >3. The FNAC results of 85% of the nodules (196 of 231) were benign, while 15% (35 of 231) had non-negative results. Hypoechogenicity, solid structure, the presence of microcalcifications, and the number of nodules were independent predictors of the final diagnosis, and the diagnostic accuracy of the TMS was good (area under the ROC curve, 0.82). CONCLUSION: The TMS system is simple to use, reliable, easily reproducible, and closely reflects malignancy risk. Based on our results, FNAC could be limited to nodules with a TMS ≥3 without missing any cases of carcinoma.

4.
Acad Radiol ; 24(7): 795-801, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28189505

RESUMO

RATIONALE AND OBJECTIVES: This study evaluates the influence of the calibrated luminance level of medical displays in the detectability of microcalcifications and spiculated lesions in digital breast tomosynthesis images. MATERIALS AND METHODS: Four models of medical displays with calibrated maximum and minimum luminance, respectively, ranging from 500 to 1000 cd/m2 and from 0.5 to 1.0 cd/m2, were investigated. Forty-eight studies were selected by a senior radiologist: 16 with microcalcifications, 16 with spiculated lesions, and 16 without lesions. All images were anonymized and blindly evaluated by one senior and two junior radiologists. For each study, lesion presence or absence and localization statements, interpretative difficulty level, and overall quality were reported. Cohen's kappa statistic was computed between monitors and within or between radiologists to estimate the reproducibility in correctly identifying lesions; for multireader-multicase analysis, the weighted jackknife alternative free-response receiver operating characteristic statistical tool was applied. RESULTS: Intraradiologist reproducibility ranged from 0.75 to 1.00. Interreader as well as reader-truth agreement values were >0.80 and higher with the two 1000 cd/m2 luminance displays than with the lower luminance displays for each radiologist. Performances in the detectability of breast lesions were significantly greater with the 1000 cd/m2 luminance displays when compared to the display with the lowest luminance value (P value <0.001). CONCLUSIONS: Our findings highlight the role of display luminance level on the accuracy of detecting breast lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Apresentação de Dados , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Mama/diagnóstico por imagem , Mama/patologia , Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/patologia , Neoplasias da Mama/patologia , Calcinose/patologia , Feminino , Humanos , Curva ROC , Reprodutibilidade dos Testes
5.
Acta Radiol ; 55(9): 1040-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24292898

RESUMO

BACKGROUND: There is a significant association between aortic atherosclerosis and previous major cardiovascular events. Particularly, thoracic aortic atherosclerosis is closely related to the degree of coronary and carotid artery disease. Thus, there is a rationale for screening the thoracic aorta in patients who undergo a chest computed tomography (CT) for any clinical question, in order to detect patients at increased risk of cerebro-cardiovascular (CCV) events. PURPOSE: To estimate the association between either thoracic aortic wall thickness (AWT) or aortic total calcium score (ATCS) and CCV events. MATERIAL AND METHODS: One hundred and forty-eight non-cardiac patients (78 men; 67 ± 12 years) underwent chest contrast-enhanced multidetector CT (MDCT). The AWT was measured at the level of the left atrium (AWTref) and at the maximum AWT (AWTmax). Correlation with clinical CCV patients' history was estimated. The value of AWTmax and of a semi-quantitative ATCS as a marker for CCV events was assessed using receiver-operating characteristic curve (ROC) analysis and multivariate regression analysis. RESULTS: Out of 148 patients, 59% reported sedentary lifestyle, 44% hypertension, 32% smoking, 23% hypercholesterolemia, 13% family history of cardiac disease, 12% diabetes, and 10% BMI ≥ 30 kg/m(2); 9% reported myocardial infarction, 8% aortic aneurism, 8% myocardial revascularization, and 2% ischemic stroke. Twenty-six percent of patients had a medium-to-high ATCS. Both AWTmax and AWTref correlated with hypertension and age (P < 0.002). At the ROC analysis, a 4.8 mm threshold was associated to a 90% specificity and an odds ratio of 6.3 (AUC = 0.735). Assuming as threshold the AWTmax median value (4.3 mm) of patients who suffered from at least one CCV event in their history, a negative predictive value of 90%, a RR of 3.6 and an OR of 6.3 were found. At the multivariate regression analysis, AWTmax was the only independent variable associated to the frequency of CCV events. CONCLUSION: Patients with increased thoracic AWTmax on chest MDCT could be considered at risk for CCV disease.


Assuntos
Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Aterosclerose/diagnóstico por imagem , Doenças Cardiovasculares/etiologia , Transtornos Cerebrovasculares/etiologia , Tomografia Computadorizada Multidetectores , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/complicações , Aterosclerose/complicações , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Fatores de Risco , Calcificação Vascular/diagnóstico por imagem
6.
Ultrasound Med Biol ; 39(8): 1350-5, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23743097

RESUMO

This study was conducted to evaluate whether ultrasound characteristics of thyroid nodules with a known cytologic diagnosis of "follicular pattern" (indicative of follicular hyperplasia, follicular adenoma or follicular carcinoma) can be used to define a nodule malignancy score to limit surgery to selected, higher-risk cases. In pre-operative ultrasound results of patients diagnosed with a "follicular pattern" on cytology who subsequently underwent surgery, each nodule feature was given a score from 0 (most likely benign) to 2 (most likely malignant), resulting in a total score ranging from 0 to 11. The total nodule score (total malignancy score) was then compared with the definitive histologic diagnosis. According to our results, surgery is advisable in patients with score ≥4 (79% of carcinomas), ultrasound follow-up seems to be appropriate for patients with a score of 3 (21% of carcinomas) and no action is recommended for patients with score <3 (only benign nodules).


Assuntos
Adenocarcinoma Folicular/diagnóstico por imagem , Adenocarcinoma Folicular/cirurgia , Índice de Gravidade de Doença , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/cirurgia , Tireoidectomia/estatística & dados numéricos , Ultrassonografia/estatística & dados numéricos , Adenocarcinoma Folicular/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Tomada de Decisões , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Nódulo da Glândula Tireoide/epidemiologia , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...